Commercial Lighting Company designs, supplies and installs commercial lighting systems for businesses, hospitals, schools and sports facilities throughout the UK.
Our lighting projects incorporate energy-efficient LED luminaires, intelligent lighting controls, exterior floodlighting and bespoke lighting designs tailored to individual property requirements.
Project: Multi-building commercial lighting refurbishment
Customer: Anthony Gresham
Company: Gresham Business Property Group
Location: Milton Keynes, Buckinghamshire
Number of Buildings: 6
Combined Floor Area: 32,400m²
Number of Luminaires: 3,840
Project Value: £346,800
Project Duration: 42 working days
Services: Commercial lighting design, LED lighting installation and intelligent lighting controls
Gresham Business Property Group managed six commercial office buildings accommodating approximately 2,100 employees across multiple businesses.
The existing fluorescent lighting systems consumed considerable electricity and required frequent maintenance. Several office areas experienced inconsistent illumination and excessive glare around computer workstations.
The customer required a comprehensive LED lighting refurbishment to improve lighting quality, reduce operational expenditure and standardise equipment across the business park.
Commercial Lighting Company assessed the existing lighting arrangements across all six buildings.
The lighting designs considered:
Open-plan office layouts
Individual workstation requirements
Meeting and conference room illumination
Reception and communal areas
Computer screen glare
Natural daylight availability
Ceiling configurations
Existing electrical infrastructure
Low-glare LED luminaires were specified for office environments, with lighting layouts developed around the requirements of BS EN 12464-1.
The refurbishment programme incorporated 3,840 LED luminaires.
The installation included:
2,480 recessed LED office luminaires
480 suspended linear LED fittings
320 meeting and conference room luminaires
360 corridor and circulation area fittings
200 reception and communal area luminaires
Individual lighting specifications reflected the operational requirements of each commercial building.
Commercial Lighting Company installed programmable lighting controls throughout suitable areas.
The control systems incorporated occupancy detection, daylight-responsive dimming and individually controlled meeting rooms.
Programmable operating schedules allowed facilities managers to reduce unnecessary lighting operation outside normal business hours.
The previous lighting installation had a combined connected load of approximately 230.4kW.
The replacement LED systems reduced the connected load to approximately 115.2kW.
Based on 3,200 equivalent annual operating hours, the projected savings were:
Annual electricity reduction: 368,640kWh
Estimated annual savings at £0.25 per kWh: £92,160
Connected lighting load reduction: 50%
Estimated simple payback period: 3.8 years
Additional savings associated with intelligent lighting controls and reduced maintenance expenditure were excluded.
Commercial Lighting Company divided the refurbishment programme into individual building and floor phases.
Installation teams completed selected works during evenings and weekends to minimise disruption to commercial tenants.
Electrical isolation, ceiling access and equipment deliveries were coordinated with individual facilities managers.
Gresham Business Property Group received modernised lighting infrastructure across six commercial buildings.
The completed programme delivered:
Installation of 3,840 LED luminaires
Improved office lighting uniformity
Reduced glare across workstation areas
Intelligent lighting controls
50% reduction in connected lighting load
Standardised lighting equipment
Reduced routine maintenance requirements
The programme was completed within forty-two working days and the agreed £346,800 budget.
Project Takeaway: Commercial LED lighting refurbishments reduce building operating costs because modern luminaires require less electricity to provide suitable workplace illumination.
Project: Comprehensive hospital LED lighting refurbishment
Customer: Dr Caroline Hextall
Company: East Midlands Clinical Facilities Group
Location: Leicester, Leicestershire
Hospital Size: 42,600m²
Number of Patient Beds: 640
Number of Luminaires: 4,280
Project Value: £542,600
Project Duration: 60 working days
Services: Hospital lighting design, LED lighting installation and adjustable lighting controls
East Midlands Clinical Facilities Group operated a large hospital incorporating inpatient wards, outpatient departments, treatment rooms, diagnostic facilities and administrative offices.
The existing lighting infrastructure relied heavily on fluorescent fittings, creating ongoing maintenance requirements and inconsistent illumination across several departments.
The customer required an energy-efficient lighting installation that accommodated clinical activities, patient comfort and continuous healthcare operations.
Commercial Lighting Company conducted a detailed lighting assessment across individual hospital departments.
The assessment considered:
Clinical examination lighting requirements
Patient ward illumination
Colour rendering performance
Visual comfort and glare control
Overnight patient care requirements
Corridor and circulation lighting
Cleaning and infection prevention requirements
Existing lighting controls
The lighting designs referenced relevant healthcare lighting guidance, including CIBSE LG2 and BS EN 12464-1.
The installation programme incorporated 4,280 LED luminaires.
The equipment included:
1,480 patient ward luminaires
760 clinical examination and treatment room fittings
920 corridor and circulation area luminaires
480 consultation and administrative room fittings
360 reception and communal area luminaires
280 staff welfare and ancillary area fittings
Individual luminaire specifications reflected the activities undertaken within each department.
Specialist surgical lighting and dedicated medical examination equipment remained outside the general lighting refurbishment scope.
Commercial Lighting Company installed adjustable lighting arrangements within selected patient accommodation areas.
The lighting controls allowed healthcare professionals to select illumination levels appropriate for routine patient care, examinations and overnight periods.
Individual patient reading lights provided additional flexibility without requiring full ward illumination.
Occupancy detection was incorporated within suitable storage rooms, staff facilities and intermittently occupied ancillary areas.
Daylight-responsive dimming controls were installed within selected reception areas and administrative offices.
Clinical departments requiring continuous lighting retained appropriate operating arrangements.
The previous lighting installation had an estimated connected load of 256.8kW.
The replacement LED system reduced the connected load to approximately 145.52kW.
Based on 6,000 equivalent annual operating hours, the projected savings were:
Annual electricity reduction: 667,680kWh
Estimated annual savings at £0.25 per kWh: £166,920
Connected lighting load reduction: approximately 43%
Estimated simple payback period: 3.3 years
Additional maintenance and lighting control savings were excluded from the calculation.
Commercial Lighting Company coordinated individual installation phases with hospital engineering departments and clinical managers.
Installation teams followed agreed infection prevention procedures and controlled electrical isolation arrangements.
Patient ward refurbishments were scheduled around bed availability, clinical activities and departmental access requirements.
Temporary lighting arrangements maintained suitable illumination where required.
East Midlands Clinical Facilities Group received upgraded lighting infrastructure throughout its hospital.
The completed project delivered:
Installation of 4,280 LED luminaires
Improved illumination across clinical departments
Adjustable patient ward lighting
Intelligent lighting controls
Approximately 43% reduction in connected lighting load
Reduced fluorescent lamp maintenance requirements
Electrical installation and commissioning documentation
The refurbishment was completed within sixty working days and the agreed £542,600 budget.
Project Takeaway: Hospital LED lighting installations improve operational efficiency because appropriately specified luminaires support clinical activities while reducing electricity consumption and routine maintenance.
Project: Multi-site educational LED lighting installation
Customer: Margaret Winfield
Company: Lancashire Educational Estates Partnership
Location: Preston, Blackburn, Chorley, Lancaster and Burnley
Number of Schools: 12
Combined Number of Pupils: 8,400
Number of Luminaires: 4,860
Project Value: £398,400
Project Duration: 30 working days
Services: School lighting design, classroom LED lighting and automated lighting controls
Lancashire Educational Estates Partnership managed twelve primary and secondary schools across Lancashire.
The existing lighting installations incorporated older fluorescent fittings that required frequent maintenance and provided inconsistent illumination across classrooms, specialist teaching areas and communal spaces.
The customer required a coordinated LED lighting refurbishment completed during the summer school holidays.
The installation needed to improve classroom visual comfort, reduce electricity consumption and provide consistent lighting specifications across the educational estate.
Commercial Lighting Company surveyed the existing lighting infrastructure across all twelve schools.
The lighting assessment considered:
Classroom dimensions and desk layouts
Interactive display positioning
Existing illumination levels
Lighting uniformity
Glare control
Science laboratory requirements
Design and technology classrooms
Assembly hall layouts
Natural daylight availability
Individual lighting designs reflected the visual requirements of different educational activities.
The refurbishment programme incorporated 4,860 LED luminaires.
The equipment included:
2,760 classroom LED luminaires
680 corridor and circulation area fittings
480 science and technology classroom luminaires
360 assembly and activity hall fittings
340 administrative and staff room luminaires
240 ancillary and welfare area fittings
Low-glare luminaires were specified for general classrooms and computer suites.
General classroom lighting designs incorporated maintained illumination targets of 300 lux where appropriate.
Higher illumination levels were specified for specialist teaching activities, including detailed practical work and laboratory tasks.
Luminaire positioning considered desk arrangements, interactive whiteboards and the distribution of natural daylight.
Commercial Lighting Company installed occupancy sensors throughout suitable corridors, toilets, storage rooms and staff facilities.
Selected classrooms received daylight-responsive dimming controls.
The automated controls reduced unnecessary electricity consumption when rooms were unoccupied or sufficient natural daylight was available.
The existing lighting installations had a combined connected load of approximately 291.6kW.
The replacement LED installations reduced the connected load to approximately 145.8kW.
Based on 2,100 equivalent annual operating hours, the projected savings were:
Annual electricity reduction: 306,180kWh
Estimated annual savings at £0.25 per kWh: £76,545
Connected lighting load reduction: 50%
Estimated simple payback period: 5.2 years
Additional savings from occupancy detection, daylight-responsive controls and reduced maintenance were excluded.
Commercial Lighting Company deployed multiple installation teams across the educational estate.
Individual refurbishment schedules were coordinated with school site managers to ensure all electrical works, testing and commissioning were completed before the autumn term.
Classroom furniture, teaching equipment and existing ceiling systems were protected throughout the works.
Lancashire Educational Estates Partnership received modern LED lighting installations across twelve schools.
The completed programme delivered:
Installation of 4,860 LED luminaires
Improved classroom lighting quality
Reduced glare within teaching environments
Automated lighting controls
50% reduction in connected lighting load
Consistent lighting specifications across all schools
Completion before pupils returned for the autumn term
The programme was completed within thirty working days and the agreed £398,400 budget.
Project Takeaway: School LED lighting refurbishments support effective teaching environments because suitable illumination and glare control improve visual comfort during classroom activities.
Project: Multi-hall sports lighting refurbishment
Customer: David Ellerby
Company: Trent Regional Leisure Facilities
Location: Nottingham, Nottinghamshire
Number of Sports Halls: 3
Combined Sports Hall Area: 3,456m²
Number of LED Sports Luminaires: 216
Project Value: £124,800
Project Duration: 15 working days
Services: Indoor sports lighting, LED sports hall lighting and programmable lighting controls
Trent Regional Leisure Facilities operated three indoor sports halls accommodating badminton, basketball, netball, volleyball and recreational activities.
The existing metal halide lighting systems provided inconsistent illumination and required lengthy warm-up periods.
The customer required a replacement LED sports lighting installation that accommodated different sporting activities, competitive fixtures and individual court bookings.
Commercial Lighting Company assessed the existing lighting installations across all three sports halls.
The assessment considered:
Individual court layouts
Existing luminaire positions
Roof structures and mounting heights
Horizontal illumination levels
Lighting uniformity
Player glare
Ball and shuttlecock visibility
Electrical infrastructure
Maintenance accessibility
The replacement lighting designs referenced BS EN 12193 and applicable sport-specific lighting guidance.
Commercial Lighting Company installed 216 LED sports luminaires across the three halls.
The installation included:
96 LED sports luminaires within the main competition hall
72 LED sports luminaires within the secondary sports hall
48 LED sports luminaires within the recreational activity hall
Suitable impact-resistant fittings and optical distributions were specified according to the intended sporting activities.
Luminaire positions considered court markings and player sightlines to manage glare.
The installation incorporated independently controlled lighting zones and programmable illumination settings.
The agreed lighting settings included:
200 lux for suitable recreational activities
300 lux for general training sessions
500 lux for appropriate competitive activities
Individual court lighting controls
Reduced-output cleaning and maintenance settings
Final lighting settings reflected the requirements of individual sports and competition levels.
The existing installation had a combined connected load of approximately 95.04kW.
The replacement LED sports luminaires reduced the connected load to approximately 51.84kW.
Based on 3,800 annual operating hours at full output, the projected savings were:
Annual electricity reduction: 164,160kWh
Estimated annual savings at £0.25 per kWh: £41,040
Connected lighting load reduction: approximately 45%
Estimated simple payback period: 3 years
Further electricity savings were possible through reduced-output lighting settings and individual court controls.
Following installation, Commercial Lighting Company conducted illumination measurements throughout the three sports halls.
The commissioning process assessed horizontal illuminance, lighting uniformity and the operation of programmable lighting controls.
Facilities managers received operating instructions covering individual lighting settings and maintenance requirements.
Trent Regional Leisure Facilities received modern LED sports lighting systems across three indoor sports halls.
The completed project delivered:
Installation of 216 LED sports luminaires
Improved playing surface illumination
Programmable lighting settings
Independently controlled court zones
Approximately 45% reduction in connected lighting load
Instant lighting activation
Reduced routine lighting maintenance requirements
The installation was completed within fifteen working days and the agreed £124,800 budget.
Project Takeaway: LED sports hall lighting improves facility flexibility because programmable lighting controls accommodate different sports, competition levels and court booking arrangements.
Project: Large-scale outdoor sports floodlighting installation
Customer: James Penrose
Company: Thames Valley Sports Development Centre
Location: Reading, Berkshire
Number of Playing Surfaces: 4
Combined Playing Area: 24,334m²
Number of Floodlighting Columns: 32
Number of LED Floodlights: 112
Project Value: £324,600
Project Duration: 30 working days
Services: Outdoor sports lighting, football pitch floodlighting and hockey pitch lighting
Thames Valley Sports Development Centre operated two full-size artificial grass football pitches and two sand-dressed hockey pitches.
Restricted floodlighting coverage limited the availability of evening training sessions and competitive fixtures during the winter months.
The customer required independently controlled LED floodlighting systems that supported extended operating hours while managing light spill towards nearby residential properties.
The floodlighting installation covered four playing surfaces:
Two football pitches measuring 105m x 68m each
Two hockey pitches measuring 91.4m x 55m each
Commercial Lighting Company developed individual photometric lighting designs around the dimensions, playing requirements and surrounding environments of each pitch.
The agreed maintained average illumination targets were 200 lux for football and 350 lux for hockey, subject to the intended competition classifications and governing body requirements.
The installation incorporated thirty-two floodlighting columns.
Eight columns were positioned around each playing surface, with mounting heights determined through structural and photometric assessments.
Column heights ranged between 12 and 18 metres.
The installation included suitable foundations, mounting arrangements and dedicated underground electrical cable routes.
Commercial Lighting Company installed 112 directional LED sports floodlights.
The equipment included:
48 football pitch LED floodlights
64 hockey pitch LED floodlights
Dedicated floodlighting distribution equipment
Independently controlled pitch lighting circuits
Directional optical systems
Programmable lighting controls
Individual floodlight aiming arrangements provided suitable playing surface coverage while managing glare and unnecessary light spill.
The floodlighting controls allowed facilities managers to operate each pitch independently.
Programmable illumination settings accommodated recreational bookings, training sessions and competitive fixtures.
Reduced-output lighting settings were commissioned where suitable for the intended sporting activities.
The independently controlled systems prevented unoccupied pitches from remaining illuminated unnecessarily.
Commercial Lighting Company conducted post-installation illumination measurements across all four playing surfaces.
The commissioning process assessed:
Horizontal illumination levels
Playing surface lighting uniformity
Individual floodlight aiming
Lighting control operation
Electrical installation performance
Boundary light spill against applicable limits
Individual luminaires were adjusted where necessary to achieve the agreed lighting specification.
The completed floodlighting installation enabled the sports centre to offer up to twenty additional bookable hours per pitch each week during periods of limited daylight.
Across four playing surfaces, this represented up to eighty additional pitch booking hours per week, subject to planning conditions and operational restrictions.
Thames Valley Sports Development Centre received four independently controlled LED floodlighting systems.
The completed project delivered:
Installation of thirty-two floodlighting columns
Installation of 112 LED sports floodlights
Sport-specific lighting designs
Improved evening training facilities
Independently controlled pitch lighting
Managed glare and light spill
Up to eighty additional bookable hours per week
Electrical installation and commissioning documentation
The installation was completed within thirty working days and the agreed £324,600 budget.
Project Takeaway: Outdoor sports floodlighting increases facility utilisation because artificial illumination allows football and hockey pitches to accommodate bookings beyond natural daylight hours.
Project: External commercial LED lighting refurbishment
Customer: Susan Cartmel
Company: Cartmel Retail Property Investments
Location: Peterborough, Cambridgeshire
External Site Area: 46,200m²
Number of Retail Units: 24
Number of Parking Spaces: 1,180
Number of LED Luminaires: 286
Project Value: £186,750
Project Duration: 22 working days
Services: Exterior commercial lighting, car park lighting, LED floodlighting and lighting controls
Cartmel Retail Property Investments managed a large retail park incorporating twenty-four commercial units, customer car parks, pedestrian routes, service yards and landscaped communal areas.
The existing exterior lighting installation provided inconsistent illumination across parking bays and pedestrian access routes.
The customer required a coordinated exterior LED lighting refurbishment that improved visibility, reduced electricity expenditure and supported evening retail operations.
Commercial Lighting Company assessed the existing external lighting infrastructure and individual areas of the retail park.
The lighting design considered:
Customer parking bay layouts
Vehicle circulation routes
Pedestrian crossings
Retail entrance areas
Delivery and service yards
Landscaped communal areas
Existing lighting columns
External building elevations
Surrounding property boundaries
Glare and obtrusive light control
Photometric modelling established suitable luminaire positions, mounting heights and optical distributions.
Commercial Lighting Company installed 286 exterior LED luminaires throughout the retail park.
The installation incorporated:
144 column-mounted car park luminaires
48 directional service yard floodlights
42 wall-mounted exterior building luminaires
32 pedestrian pathway lighting fittings
20 landscape and entrance area luminaires
Weather-resistant lighting equipment was specified according to the environmental conditions and operational requirements of each area.
The installation retained forty-eight existing lighting columns following appropriate structural assessments.
Replacement brackets and electrical connections accommodated the new LED luminaires.
Retaining suitable existing infrastructure reduced the requirement for excavation, replacement foundations and additional civil engineering works.
Commercial Lighting Company installed photocell controls and programmable lighting schedules.
The control systems automatically activated exterior lighting when natural daylight fell below the configured threshold.
Selected service areas received motion-responsive lighting controls, allowing reduced illumination during inactive periods where appropriate.
The previous exterior lighting installation had a combined connected load of approximately 114.4kW.
The replacement LED system reduced the connected load to approximately 54.34kW.
Based on 4,100 equivalent annual operating hours, the projected savings were:
Annual electricity reduction: 246,246kWh
Estimated annual savings at £0.25 per kWh: £61,561.50
Connected lighting load reduction: approximately 52.5%
Estimated simple payback period: 3 years
Additional savings associated with automated lighting controls and reduced maintenance were excluded.
Commercial Lighting Company divided the retail park into individual installation zones.
The installation teams coordinated temporary parking restrictions, access equipment movements and electrical isolation with retail property managers.
Selected works took place outside peak shopping periods to minimise disruption to customers and commercial tenants.
Cartmel Retail Property Investments received modern exterior LED lighting infrastructure across its retail park.
The completed project delivered:
Installation of 286 exterior LED luminaires
Improved car park illumination
Enhanced pedestrian route visibility
Upgraded service yard floodlighting
Retention of forty-eight suitable lighting columns
Automated exterior lighting controls
Approximately 52.5% reduction in connected lighting load
Reduced external lighting maintenance requirements
The project was completed within twenty-two working days and the agreed £186,750 budget.
Project Takeaway: Exterior commercial LED lighting reduces operating expenditure because efficient luminaires and automated controls limit unnecessary electricity consumption across large external areas.
Commercial Lighting Company provides commercial lighting installations, hospital lighting, school lighting, indoor sports lighting and outdoor sports floodlighting throughout the UK.
Our team delivers bespoke lighting designs, energy-efficient LED installations, intelligent lighting controls and large-scale lighting refurbishment programmes.
Contact us today to discuss your commercial lighting requirements.
Commercial Lighting Company is a trading style of PPG M&E, Sports & Horticultural Lighting Ltd, registered in England & Wales (company no: 13582869)